Truss Anchor

The TA secures trussed rafters to 2 ply wall plates or head binders whilst providing a positive fixing on two planes.

  • Suitable for use with solid timber header (min. C16)
  • Eliminates damage from skew nailing into the wall plate
  • “Push on” fit allows truss anchor to be retained in position prior to nailing
Z275

Galvanised Mild Steel

Up to 7.54kN

Load Direction Specific

CE marking shows that a product meets EU safety and regulatory requirements.

ETA (European Technical Assessment) is a document that assesses the performance of a construction product not fully covered by a harmonised standard.

UKCA marking shows that a product meets the UK’s safety and regulatory requirements.

EPD (Environmental Product Declaration) is a verified document that reports a product’s environmental impact across its lifecycle. View EPD

Service class defines the environmental and use conditions a construction product is designed to withstand during its intended lifetime.

NHBC (National House-Building Council) sets standards and provides warranties and inspection services for new homes in the UK. NHBC Approved

Eliminates damage from skew nailing into the wall plate

“Push on” fit allows truss anchor to be retained in position prior to nailing

Optional triangular nail holes for enhanced performance

Eliminates the need for a pre-cut angle barer to support the valley truss or pre-cut angle to valley truss

Cullen products have been tested and CE marked to the requirements of ETAG015 using 3.4 x 35mm square twist nails.

  1. Double wall plate required for all installations (min. 75mm) unless using in a timber frame application where the framing anchor can be fitted to the head binder.
  1. Double wall plate required for all installations (min. 75mm) unless using in a timber frame application where the framing anchor can be fitted to the head binder.
  1. Double wall plate required for all installations (min. 75mm) unless using in a timber frame application where the framing anchor can be fitted to the head binder.

The TA can be used in conditions where the supporting truss is a maximum 45° slope. Fill the 3 nail holes highlighted above to the supporting truss (dependant on TA orientation) and fill 4 no. nail holes (2 no. each face) for the incoming truss for correct installation.

Double wall plate required for all installations (min. 75mm) unless using in a timber frame application where the framing anchor can be fitted to the head binder

The TA can be used in conditions where the supporting truss is a maximum 45° slope. Fill the 3 nail holes highlighted above to the supporting truss (dependant on TA orientation) and fill 4 no. nail holes (2 no. each face) for the incoming truss for correct installation

Support you can rely on

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.